Applicable to muscle and bone pain, arthritis, soft tissue injuries, and promoting wound healing.
Automatically set parameters: A truly intelligent analysis system can automatically match treatment parameters based on skin color, hair density, and thickness.
Realize a variety of treatment spots with one handle, save machine costs, and quickly return funds.
Spot Sizes: 12*12 mm², 12*20 mm², 15*27mm², 12*35 mm² (optional)
Control via phone calls and text messages without internet:
Two methods can be adopted: leasing time or leasing points. The startup password is calculated based on the big data system. Users can input the startup password received via phone calls, text messages, etc., even without a network connection. The operation can be completed without the physical presence of after-sales personnel.
Supports multiple models of mobile phones. Mobile screen, controller screen, and host screen operate in linkage.
Passed the American Tracepro optical experimental data test, the light energy transmittance is 96.5%. Features USA Coherent imported laser bars with full certification. Built with magnetic force + fixing pin + curved edge teeth, preventing handle head light leakage for a stronger fit.
| Feature | Our Laser System | Others |
|---|---|---|
| Identify | Intelligent AI recognition technology (System automatically identifies the installed spot and automatically adjusts parameters) | No automatic recognition |
| Risk | Intelligently adjust parameters to avoid burns or insufficient energy | Easy to get burned or lack energy during adjustment |
| Light Loss | Passed the American Tracepro optical test, light energy transmittance is 96.5% | Failed the light decay test |
| Transmission | Wireless transmission, no contact failure issues | Wired transmission is prone to poor contact or loss of data |
| Fixed Way | Magnetic force + fixing pin + curved edge teeth (no light leakage, stronger fit) | Magnetic only (light source easily diverges and deforms) |
| Chip | USA Coherent imported laser bar with certification | No certification |
| Energy Rate | Energy utilization rate is over 95% | Energy utilization rate is only 60% |
| Certification | MDSAP, Medical CE, TGA, TUV | No MDSAP, TGA |
| Parameter | Details |
|---|---|
| Laser Type | Diode laser |
| Laser Wavelength | 808nm or 3 wave (755nm & 808nm & 1064nm) |
| Spot Size | 12*12 mm², 12*20 mm², 15*27mm², 12*35 mm² (optional) |
| Pulse Width | 1-400 ms (adjustable), 300ms, 200ms (optional) |
| Energy | 1-160 J/cm² (adjustable), 280J, 360J (optional) |
| Frequency | 1-10 Hz (adjustable) |
| Language Support | English, Spanish, Italian, German, French, Turkish or other requested languages |
| Skin Type | I-VI skin types |
| Update System | USB update |
| Rent System | Optional |
| Display | 12.4 inch / 15 inch color touch LCD display |
| Laser Module Power | 600W / 800W / 1000W / 1200W / 1600W |
| Cooling System | Water + air + semiconductor + A/C + TEC big cooler parts |
| Voltage | 110V/220V±20V, 50/60Hz |
We are a professional manufacturer focusing on the development of beauty devices since 2009. All products carry CE and ISO certifications suitable for the global market, primarily North America, South America, and Europe. Our aim is to develop high-quality beauty equipment that makes your business easier.
Q1: Which certifications do your laser machines hold?
A1: Our manufacturing processes and products are certified under ISO 13485 (MDSAP and TUV medical device system certification) and Medical CE (TUV 93/42/EEC standard). They are also certified for use in 27 EU countries, Brazil, New Zealand, Japan, Canada, and the United States.
Q2: How does the AI intelligent skin analysis system improve treatments?
A2: The system automatically detects skin color, hair density, and hair thickness to set the optimal parameters. This prevents clinical errors, such as skin burns or inadequate energy delivery during treatment.
Q3: How does the offline leasing system function?
A3: The system allows control through leasing time or points. It generates startup passwords calculated by a big data system. Users can receive and use these passwords via phone calls or SMS without needing an internet connection, removing the need for on-site support.
Q4: What is the energy efficiency of your laser system?
A4: Due to double-row lasers and premium USA Coherent imported laser bars, our system achieves an energy utilization rate of over 95%. It has passed the American Tracepro optical test with a light energy transmittance of 96.5%.
Q5: What are the benefits of the newly added physical therapy function?
A5: The physical therapy function is designed for muscle and bone pain, arthritis, and soft tissue injuries. It helps by penetrating deep tissue, stimulating cellular energy (ATP), reducing inflammation, relieving pain, and accelerating recovery.
Q6: What spot sizes are supported by the handle?
A6: One handle supports multiple treatment spots to lower machinery costs. Standard sizes include 12*12 mm², 12*20 mm², and 15*27mm², with an optional 12*35 mm² size available.